McKenna / Mobitec ICU400 Controller
The ICU 400 Controller is a user-friendly device for operating Mobitec sign systems in public-transport vehicles. Route numbers, destination text and graphics can be simply and quickly updated using the MobiQuickCard™, which enables up to 10,000 destination texts to be transferred from the flashcard to the control unit, having been programmed using Mobitec's editing software called Mobi Info Edit.
SIMPLE FOR THE DRIVER
A small number of intuitive buttons make it simple for the driver to select route number, destination text and graphics.
The display shows exactly the same information as the sign and has background illumination, making things easier for the driver on night-time journeys.

QUICK UPDATING
Route number, destination text and graphics are created in an easy-to-use editing program.
The file is downloaded quickly and simply from the computer via a diskette adapter to our MobiQuickCard?. The information is transferred via the card to the control unit on board the vehicle. No PC or cable is required.

EASY TO INSTALL
With its small cut-out and overall dimensions, the ICU400 is simple to install and easy to position in the bus. Just one cable is normally needed to connect the control unit.


TECHNICAL DATA
Voltage

Nominal
Supply

24v DC
18 - 32v DC
Power Consumption

Operating
Standby

50 mA
3 mA
Data Communication   RS485 or IBIS
Text transfer   MobiQuickCard (SSFDC) or Mobitec Loader
Transfer speed   Varies with number of destinations, e.g. 1000 destinations in approx. 15 seconds (15-50Kbytes/sec)
Memory   Flashprom, 1MB
Display   Graphic LCD - Backlit
Ambient Environment Temperature Range
Relative Humidity
Vibration
Shock
-30 to +70° C
<93% RH at +40° C
IEC 68-2-64-Fh
IEC 68-2-27-Ea
Body dimensions (L x H x D mm)   121 x 62 x 38
Overall dimensions (L x H x D mm)   143 x 68 x 46